477738 Retrograde and Phase Change (RPC) Flow Considerations for Relief and Flare Systems

Monday, March 27, 2017: 5:48 PM
Exhibit Hall 3 (Henry B. Gonzalez Convention Center)
Georges Melhem, ioMosaic, Salem, NH

Retrograde and Phase Change (RPC) Flow Considerations for Relief and Flare Systems

G. A. Melhem, Ph.D., FAIChE

ioMosaic Corporation 93 Stiles Road

Salem, New Hampshire 03079

<>1        Abstract

Retrograde and phase change (RPC) flow considerations are important for relief and flare systems design and evaluations. RPC flow can occur in high pressure systems, including subcooled and/or supercritical flow, or at lower pressures where the starting relief conditions are close to a phase boundary. RPC flow is also encountered in other flow systems applications such as gas transmis- sion pipelines for example.

This type of flow can present technical challenges in relief and flare systems design and evaluations for pure components and mixtures alike. Proper consideration of RPC flow is essential for the evaluation of:

     Proper relief device sizing, selection, and installation,

     Pressure Relief Valve (PRV) stability,

     Depressuring systems,

     Piping vibration risk,

     Temperature estimates in downstream piping, i.e. metallurgy considerations, and

     Effluent handling and flare systems design.

This paper discusses best practices for the identification of RPC flow and for the numeric evaluation of associated choking pressures, temperatures, flow rates, and compositions. Two examples dealing with pure ethylene and an ethylene-butyl acrylate mixture are used to illustrate a variety of concepts dealing with RPC flow.

<>2        RPC Flow Scenarios

We divide scenarios dealing with RPC flow into three general categories where the initial starting conditions of the mixture or pure component can be classified as:


Liquid Saturated (L1), subcooled (L2), and supercritical liquid (L3),   Vapor Saturated, (V1), superheated (V2), and supercritical vapor (V3), and Two-phase  Saturated (T1) and/or retrograde two-phase vapor/liquid (T2).

This is illustrated for pure ethylene in Figure 1 and for a mixture of ethylene (94 weight %) and butyl acrylate (6 weight %) in Figure 2. For a pure component, the phase envelope is the saturation or vapor pressure curve.

A pure component can exist as either saturated vapor (V1), saturated liquid (L1), or a saturated two- phase mixture (T1) at the same temperature and pressure. At temperatures greater than the critical temperature, the vapor (V3) is a supercritical vapor at all pressures of interest. At temperatures below the critical temperature, the vapor (V2) is a superheated vapor because the temperature is greater than the saturation temperature. A liquid is a subcooled liquid (L2) at temperatures below the saturation temperature and pressures below the critical pressure. A liquid is a supercritical liquid (L3) at pressures in excess of the critical pressure and temperatures less than the critical temperature.

Figure 1: RPC Flow Categories for pure Ethylene

Unlike a pure component, a mixture cannot exist as a saturated liquid (bubble point), saturated vapor (dew point), and as a two-phase mixture at the same temperature and pressure as shown in Figure 1. The critical point of a mixture is not always less than the temperature at the point of maximum pressure (cricondonbar) and mixtures can sometimes have multiple critical states. For


this particular example of ethylene-butyl acrylate, the critical temperature is below the temperature at the cricondonbar. It is always important to construct a phase envelope of the mixture of interest before any flow calculations are attempted.

Figure 2: RPC Flow Categories for Ethylene-Butyl acrylate mixture

Depending on the starting conditions, a multitude of possible RPC flow scenarios are possible. If the starting pressure is high enough, choking conditions can be reached at the same phase as the starting phase. This is even possible for liquids at extremely high pressures since liquids are slightly compressible. For these scenarios, phase change almost always occurs following the expansion discontinuity after the first choke point leading to very cold temperatures. If discharge piping is present with expansions, multiple choke points can be possible. At extreme pressures above the inversion curve limit (Joule Thompson coefficient equals 0), the resulting choke temperatures may not be as cold due to JT expansion heating as shown later for the mixture of ethylene-butyl acrylate at starting pressures of 30,000 psig.

As the starting pressure is decreased, choking will occur at the phase boundary, i.e. at the bubble point for L2 and L3 flows, and at the dew point for V2 and V3 flows (if the starting vapor tem- perature is low enough and the starting liquid temperature is high enough). Further reduction in pressure can result in choking inside the two-phase region, T1.

For saturated vapor flow or vapor flow near the phase boundary, it is possible the phase change will occur at the throat or nozzle of the flow limiting element, and then the two-phase mixture will disappear after the expansion discontinuity.


Starting conditions in region T2 are particularly challenging for RPC flow since we now have a two-phase mixture at conditions in excess of the critical temperature and pressure. Initial con- ditions near the cricondonbar or critical point can result in choking inside the retrograde region T2. RPC flow estimates require robust flow and VLE solvers to figure out the ending state of the flowing fluid as the pressure is decreased due to flow in a nozzle or a pipe.

<>3        Nozzle Flow

The final conditions for nozzle flow are determined using an isentropic thermodynamic flow path. The final pressure, temperature, phase, and composition are those at which mass flow is maxi- mized [1, 2]. Figure 3 illustrates the nozzle isentropic thermodynamic flow path for the mixture of ethylene and butyl acrylate at different starting temperatures and 2000 psig. As the starting temperature is decreased the choke point phase of maximum flow shifts from vapor, to two phase, and then to saturated liquid. Note that at the 50 C starting condition the flow path goes through the critical point and ends up close to the bubble point boundary in the two phase region. We also note that the final choking temperature for highly subcooled liquid flow is very close to the value of the starting temperature since the liquid is only slightly compressible. As the flow expands from the choke point to lower pressures, it is possible to cross the phase boundaries if the pressure is low enough. If the flow is expanding into a pipe with a larger flow area, it is possible to cross the phase boundaries and to have multiple chokes downstream of the first choke. For choked (sonic) flow, the flow is always regulated by the first choke. However, subsequent chokes typically occurring at area changes such as sudden expansions in the discharge piping, can reduce the capacity of a pressure relief valve due to the increase of backpressure.

If we increase the starting pressure to 30,000 psig for the ethylene-butyl acrylate mixture we notice that these starting conditions are well above the inversion curve for the mixture. An inversion curve represents the zero limit of the Joule-Thompson (JT) coefficient. At points above the inversion curve, a negative JT coefficient indicates that as the pressure is decreased the temperature should increase, while a positive JT coefficient indicates the opposite. It is a very good practice to establish an inversion curve for high pressure systems before attempting flow estimates.

This JT coefficient is expressed in terms of the change of temperature with respect to pressure at constant enthalpy, µH . At high pressures, negative values of µH indicate an increase in temperature for a constant enthalpy pressure drop. At low pressures, positive values of µH indicate a decrease in temperature for a constant enthalpy pressure drop.

(1)

(2)

where Cp is the real fluid heat capacity at constant pressure. Equation 2 can be used to construct a complete inversion curve, a curve that represents the locus of all the zero values of the Joule- Thompson coefficient. Figure 4 displays an inversion curve calculated by SuperChems using the


Figure 3: Isentropic nozzle flow for ethylene-butyl acrylate mixture at 2000 psig

Melhem modification of the Peng-Robinson equation of state for hydrogen. Hydrogen is depres- sured using both an isenthalpic and an isentropic thermodynamics paths from 1500 psig and 100 C to the flow choke point. As shown in Figure 4, the isenthalpic path heats up to 100.6 C while the isentropic path cools down to 34.7 C. For an ideal gas, β = 1/T and the Joule-Thompson coefficient is equal to 0. At critical conditions, it can be shown that µH will approach:

(3)

The inversion curve represents a severe test of the performance of an equation of state. Figure 5 illustrates the impact of JT on the final temperature reached at choking conditions. For example, the temperature only drops from 200 C to approximately 140 C despite a pressure drop from 30000 psig to 9300 psig. This is attributed to the selected thermodynamic path for flow illustrated in Figure 5 which is isentropic for an ideal nozzle and not isenthalpic.

<>4        Pipe Flow

Unlike nozzle flow, the final conditions for pipe flow are determined by conserving stagnation enthalpy. The final pressure, temperature, phase, and composition are those at which the maximum possible flow can traverse the entire pipe and still reach the choke point at exactly the end of the


Figure 4: Calculated inversion curve for Hydrogen

pipe and/or the flow limiting element. In relief systems applications, choking typically occurs at the nozzle of a pressure relief valve, a control valve, or at a change of flow area in the piping system. Multiple chokes are possible if the starting pressure is high enough. For many applications, phase change will occur after the pressure expansion following the choke location.

For relief systems piping consisting of pipe segments and a pressure relief valve and/or a control valve, the flow through these devices is still established using isentropic flow because choking typically will occur at the valve. However, the approach velocity to the nozzle has to be accounted for when calculating stagnation enthalpy via an isentropic flow path. The piping flow solvers will try to push as much mass flow as possible through the relief systems piping. If the flow is choked at the relief device or control valve, the choke point is established iteratively until the maximum mass flow rate requested by the pipe solvers matches the one established by the nozzle solvers.

We consider the flow of pure ethylene from a relief line with a short 1 m inlet line (3 inch) and a 10 m discharge line (4 inch) and a 3K4 pressure relief valve. The starting conditions are 100 barg and 10 C. As illustrated in Figure 6 the flow chokes at the two phase boundary since the starting temperature was slightly above the critical temperature of ethylene. We notice the small pressure drop in the inlet line, followed by choking at the phase boundary, and then flashing after the choke discontinuity. We note that this flow is choked at the nozzle and the exit of the discharge line.

Also shown in Figure 6 is the vapor quality as a function of piping axial distance. All vapor flow is present in the inlet line, followed by liquid at the choke point, and a two-phase mixture in the discharge line. The final exit conditions at the end of the discharge are choked at -32 C, 17.25 barg,


Figure 5: Isentropic nozzle flow for ethylene-butyl acrylate mixture at 5000, 10000, and 30000 psig

and a mass vapor quality of 37 %.

<>5        Why Consider RPC Flow

Improper calculation of RPC flow, especially for subcooled liquid flows near the liquid phase boundary, can result in undersized pressure relief devices. This is because the actual RPC mass flow rate can be substantially less than the single phase (all liquid) mass flow rate due to choking at the phase boundary which leads to less pressure differential to drive the flow across the nozzle. Conversely, for all vapor initial conditions, condensation in the valve can also reduce the valve capacity.

In addition to undersizing of the relief devices, RPC choking conditions also influence the final temperatures reached in the flow limiting element and discharge piping. This can lead to designs that are not safe because of poor piping materials selections for a temperature service that can be well below the embrittlement temperature of carbon steel depending on the chemical(s) used and relief conditions. Other important design considerations for relief systems include vibration risk and effluent handling.


Figure 6: Pressure profile for relief systems piping with starting ethylene conditions at 100 barg and 10 C

<>6        Guidance for Using SuperChems Expert

Versions 8.20 and higher of SuperChems include options for solving flow applications where RPC flow is possible. The ”Globals Calculations Limits” option includes choices for checking the phase boundaries during flow and for the selection of nozzle flow integration methods. This option is most effective in conjunction with the selection of VdP integration for nozzle flow. The option for checking phase boundaries should not be enabled when flow maps are being used for flare systems calculations with the ideal gas behavior option.

The user should always establish a phase envelope or a saturation curve before attempting any flow calculations. Inversion curves can be associated with streams in SuperChems and are very useful for high pressure applications. Although the SuperChems pipe flow and nozzle flow modules allow the user to specify the starting phase of flow, it is highly recommended to allow the module to determine the starting phase by selecting the ”Determine Flow Phase” option. Care must be exercised when dealing with pure components where the starting temperature is very close to the saturation point due to small deviations of the vapor pressure equations used. In these cases, a better approach is to specify the pressure and starting vapor fraction and to let the code select the coincident temperature. Use of the ideal nozzle or stream flow options in conjunction with flashing of the choke point (by conserving stagnation enthalpy) to ambient or user imposed back pressure will help the user select the appropriate pipe flow module.


When the phase boundary check options are enabled, the single phase piping flow modules will detect phase change and issue an error or warning message to the user recommending the use of the two-phase pipe flow module.


<>References

[1] G. A. Melhem. Superchems ideal nozzle flow models enhancements - supercritical and sub- cooled flow. In DIERS Users Group Meeting, Las Vegas, 2008.

[2] G. A. Melhem.  On the selection of two phase flow methods for ERS design.  In European DIERS Users Group Meeting, 2005.


Extended Abstract: File Not Uploaded
See more of this Session: GCPS Electronic Poster Session
See more of this Group/Topical: Global Congress on Process Safety