211353 Mitigation of Fouling In Pre-Heat Trains

Wednesday, March 16, 2011: 10:00 AM
Field (Hyatt Regency Chicago)
Graham T. Polley1, D. Ian Wilson2 and Edward Ishiyama2, (1)Chemical Engineering, Universidad de Guanajuato, Guanajuato, Mexico, (2)Chemical Engineering and Biotechnology, University of Cambridge, Cambridge, United Kingdom

Fouling of pre-heat train exchangers can be mitigated in various ways.

These include changes to exchanger design: switching from tube-side to shell-side; installing tube inserts; replacement tube bundles.

They also include modifications to the structure of pre-heat trains.

Means by which suitable modifications can be identified are described.


Extended Abstract: File Uploaded