Initial simulant Chemical Process Cell (CPC) flowsheet studies have indicated unacceptable levels of IsoparŪL were collecting in the Sludge Receipt and Adjustment Tank (SRAT) condenser system and unanticipated quantities of modifier were carrying over into the SRAT condenser system. The second round of testing included the incorporation of the MCU stream and identified potential processing issues with the MCU solvent. 3,4 The identified issues included the potential carry-over and accumulation of the MCU solvent components in the CPC condensers and in the recycle stream to the Tank Farm. Solvent retention in the DWPF condensers contradicts the DWPF solvent control strategy. Therefore, DWPF requested SRNL to perform additional MCU flowsheet studies to better quantify the organic distribution in the CPC vessels.
A total of ten 4-liter SRAT runs were performed to meet the objectives of the testing. The first series of five tests evaluated the organic portioning and mass balance for the addition of 50 mg/kg solvent. The second series of five tests evaluated the organic portioning and mass balance for the addition of 125 mg/kg solvent. A solvent concentration of 50 mg/kg is close to the nominal concentration anticipated in the effluent from the Salt Waste Processing Facility (SWPF). All runs targeted 150% acid stoichiometry and 1% mercury in the sludge slurry dried solids. The results of this testing will be reported.